Resolution
Resolution is the ability of an equipment/combination probe to distinguish between two echoes from reflectors that are close together. To have good resolution a probe must present two signals on a CRT screen from two separate reflectors: if it has poor resolution the echoes from the two reflectors appear as one signal on the screen.
In the early days of ultrasonic testing we used the 100, 91 and 85mm steps, at the radius end of the V1 block to test resolving power. However, today this is regarded as too crude a test and BS 4331 Part 3 (now obsolete) recommended that we should be able to recognise two discrete echoes less than two wavelengths apart. By discrete echoes they mean split by more than 6dB, or to more than half the total height of the signals.
رزولوشن، توانایی دستگاه و مبدل (Probe) یعنی ترکیبی !!! در تشخیص و تفکیک دو اکو از دو بازتابندهای است که فاصله بسیار کمی از یکدیگر دارند.
برای اینکه یک مبدل رزولوشن خوبی داشته باشد، باید بتواند دو سیگنال مجزا از دو بازتابنده جداگانه را روی صفحه نمایش (CRT) نشان دهد. اگر رزولوشن ضعیف باشد، اکوهای دو بازتابنده به صورت یک سیگنال واحد روی صفحه ظاهر میشوند.
در سالهای اولیه آزمون التراسونیک، از پلههای 100، 91 و 85 میلیمتری در انتهای شعاعی بلوک V1 برای ارزیابی قدرت تفکیک استفاده میشد. اما امروزه این روش آزمون نسبتاً ابتدایی و غیردقیق تلقی میشود.
استاندارد BS 4331 Part 3 (که اکنون منسوخ شده است) توصیه میکرد که دستگاه باید بتواند دو اکوی مجزا را از بازتابندههایی با فاصله کمتر از دو طول موج تشخیص دهد.
منظور از اکوهای مجزا (Discrete Echoes) این است که دو اکو باید بیش از ۶ دسیبل از یکدیگر جدا باشند؛ یعنی افت بین دو قله بیش از ۶ dB باشد، یا به عبارت دیگر، دره بین دو قله به کمتر از نصف ارتفاع کل سیگنالها برسد.